Published September 2021
NDS Staff Publication

Fast-neutron induced reaction cross section measurement of tin with dual monitor foils and covariance analysis

Description

The fast-neutron induced elemental cross sections have been measured relative to the 197Au(n,2n)196Au and 27Al(n,α)24Na monitor cross sections at 14.5 � 0.2 MeV by using a natural Sn sample and the activation technique for production of 111Sn, 117Snm, 123Snm, 111In (cumulative), 116Inm1+m2, 117Inm, 117Ing (cumulative), and 118Inm1+m2. The off-diagonal weighted mean of the elemental cross sections were determined by constructing the covariance between the cross sections obtained with the two monitor cross sections. From the measured elemental cross sections, the respective isotopic cross sections were also determined for the 112Sn(n,2n)111Sn, 124Sn(n,2n)123Snm, 112Sn(n,x)111In and 118Sn(n,p)118Inm1+m2 reactions. The comparison of the measured elemental and isotopic cross sections with those in the EXFOR, JEFF-3.1/A, JENDL/AD-2017 and TENDL-2019 libraries as well as those predicted by TALYS-1.9 is discussed.