Published June 2016
NDS Staff Publication
Neutron capture cross section measurements for 238U in the resonance region at GELINA
Description
Measurements were performed at the time-of-flight facility GELINA to determine the 238U(n,γ)
cross section in the resonance region. Experiments were carried out at a 12.5 and 60m measurement station.
The total energy detection principle in combination with the pulse height weighting technique was applied
using C6D6 liquid scintillators as prompt γ-ray detectors. The energy dependence of the neutron flux
was measured with ionisation chambers based on the 10B(n,α) reaction. The data were normalised to the
isolated and saturated 238U resonance at 6.67 eV. Special procedures were applied to reduce bias effects due
to the weighting function, normalization, dead time and background corrections, and corrections related
to the sample properties. The total uncertainty due to the weighting function, normalization, neutron
flux and sample characteristics is about 1.5%. Resonance parameters were derived from a simultaneous
resonance shape analysis of the GELINA capture data and transmission data obtained previously at a
42m and 150m station of ORELA. The parameters of resonances below 500 eV are in good agreement
with those resulting from an evaluation that was adopted in the main data libraries. Between 500 eV and
1200 eV a systematic difference in the neutron width is observed. Average capture cross section data were
derived from the experimental capture yield in the energy region between 3.5 keV and 90 keV. The results
are in good agreement with an evaluated cross section resulting from a least squares fit to experimental
data available in the literature prior to this work. The average cross section data derived in this work were
parameterised in terms of average resonance parameters and included in a least squares analysis together
with other experimental data reported in the literature.