Published 2021
NDS Staff Publication
Which nuclear data can be validated with LLNL pulsed-sphere experiments?
Description
It is shown here that 14-MeV D+T LLNL pulsed-sphere experiments bring complementary information
into the process of validating nuclear data compared to experiments that are traditionally used for this
purpose?such as critical assemblies. To be more specific, the 14-MeV D+T LLNL pulsed-sphere
neutron-leakage spectra enable to validate scattering and fission nuclear data up to 15 MeV (compared
to approximately up to 5 MeV when using criticality experiments) and employ to this end simple compound
targets containing only few isotopes. Sensitivity profiles of the spectra to nuclear data are calculated
in order to understand in detail which isotopes, observables, and energy ranges of nuclear data
contribute significantly to their simulation. These profiles are presented for a few selected spheres containing
16O, 12C, 56Fe, and 239Pu. It is shown that the neutron-leakage spectra of spheres containing light
elements are mostly sensitive to elastic- and inelastic-scattering cross sections on discrete levels and corresponding
angular distributions. Spheres of structural materials are sensitive to elastic- and inelastic scattering
cross sections, including scattering on discrete levels and the continuum, and double differential
cross sections. Actinide spheres are also strongly sensitive to the fission observables, in particular
to the total-fission neutron spectrum. Thin spheres (in which neutrons experience on average less
than one scatter) are mostly sensitive to data near the elastic peak, in the energy range from 12-15 MeV,
while thicker ones can be sensitive to data at lower incident-neutron energies due to multiple-scattering
effects. This information is brought together with simulations of 71 pulsed-sphere neutron-leakage spectra
using the ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear-data libraries. This analysis highlights ENDF/BVIII.
0 data that could be further investigated for potential shortcomings (6Li, 12C, 16O, 24-26Mg, 27Al,
48Ti, 56Fe, and 208Pb) or are likely reliable (1,2H, 7Li, 9Be, 14N, 235,238U, and 239Pu) as indicated by validating
with LLNL pulsed-sphere experiments.