Published April 2012
NDS Staff Publication
Measurement and resonance analysis of the 237Np neutron capture cross section
Description
The neutron capture cross section of 237Np was measured between 0.7 and 500 eV at the CERN n_TOF facility
using the 4π BaF2 Total Absorption Calorimeter. The experimental capture yield was extracted minimizing all the
systematic uncertainties and was analyzed together with the most reliable transmission data available using the
SAMMY code. The result is a complete set of individual as well as average resonance parameters [D0 = 0.56(2) eV,
γ = 40.9(18) meV, 104S0 = 0.98(6), R = 9.8(6) fm]. The capture cross section obtained in this work is in
overall agreement with the evaluations and the data of Weston and Todd [Nucl. Sci. Eng. 79, 184 (1981)], thus
showing sizable differences with respect to previous data from Scherbakov et al. [J. Nucl. Sci. Technol. 42, 135
(2005)] and large discrepancies with data Kobayashi et al. [J. Nucl. Sci. Technol. 39, 111 (2002)]. The results
indicate that a new evaluation combining the present capture data with reliable transmission data would allow
reaching an accuracy better than 4%, in line with the uncertainty requirements of the nuclear data community for
the design and operation of current and future nuclear devices